25
Oct 2023
The correct choice of method for testing is very important.
The shaft from the photo was originally tested by the penetration method (PT). The indication was detected, but it was more pronounced when confirmed by the magnetic-powder method.
Of course, we performed the tests under UV light, for the purpose of the photo the color method was used.